Wooster growth chamber table
ChamberTypeCharacteristicsLight - Intensity (micromoles/m2/s)Size, In. (WxDxH)Cost per day
101BDW-80Walk-in111093x125x95$3.00
102-107BDR-16Reach-in80073x32x65$2.50
108-109BDW-40Walk-in110093x62x95$2.75
110PGW-36Walk-in90098x54x80$3.00

Chambers 101-109 all have:

  • Manufactured by Conviron
  • Downward airflow
  • HID lighting (Sodium and Metal Halide) with clear Plexiglass barrier
  • Temperature Range of 10 C° to 40 C° with lights on & 4 C° to 40 C° with lights off
  • Humidification
  • Stainless steel walls
  • Lockable
  • Chamber 110 has non-barriered lighting (fluorescent and incandescent), temperature range of 10 C° to 45 C° with lights on & 4 C° to 45 C° with lights off.

Alarm capability of the growth chambers

  1. The growth chambers use tracking alarms, that is, relative to set point.
  2. The chamber alarms if temperature deviates more than 2 C° from set point.
  3. The alarm triggers a dialer on the Central Control Computer.
  4. The dialer calls the cell phones of greenhouse personnel with the alarm message.
  5. Greenhouse personnel are able to call the Central Control Computer from home to determine the cause of the alarm and sometimes fix the problem remotely. Otherwise, someone drives in and fixes the problem on site.
  6. The alarm system is tested weekly for proper function.

Data collection in the growth chambers

  1. Temperature and humidity are logged every 2 minutes to a Central Control Computer.
  2. Data is archived - daily summaries are available.
  3. Printouts of programs are kept in a notebook for later reference.4. A light meter is available for light measurements before, during, and after an experiment.
  4. We also have a Licor LI-1800 spectroradiometer to measure light intensity at different wavelengths.

Growth chamber sanitation practices

  1. Chambers are swept and vaccumed to remove soil, dirt, plant debris, etc.
  2. Chambers are washed out with RO water to remove any remaining soil or debris.
  3. Chambers are "cooked" at 45 C° (113 F°) for a minimum of 60 hours to kill insects and pathogens.
  4. Chamber walls are cleaned and polished to remove water spots and provide maximum light reflectance from chamber walls.

 

HCS Wooster walk-in growth chamber fees

Chamber #

Type

Size

Fees

10

Refurbished BDW-80

80 ft2 

$4.50 / day 

8

Refurbished BDW-40

40 ft2 

$4.00 / day 

9

Refurbished BDW-40

40 ft2 

$4.00 / day 

11

New BDW-40 low Temp and option for supplemental CO2 

40 ft2 

$5.50 / day no CO2 

$6.50 / day with CO2 

HCS Wooster reach-in growth chamber fees

Chamber #

Type

Size

Fees 

12

New PGR15 reach-in, low temp

16 ft2 

$3.50 / day 

13

New PGR15 reach-in 

16 ft2 

$3.50 / day 

14

New PGR15 reach-in 

16 ft2 

$3.50 / day 

Liquid nitrogen

Historical rates will move here as prices change throughout the years.

Plant metabolites analysis

Historical rates will move here as prices change throughout the years.

Forage and gas analysis

Historical rates will move here as prices change throughout the years.

Phytochemical analysis

Historical rates will move here as prices change throughout the years.

Field soybean breeding

Historical rates will move here as prices change throughout the years.

Page last updated - June 2026